UPS CS 638

PRODUK ICA UPS dan STABILIZER

ICA UPS CS-638 Capacity 600 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.

TECHNICAL INFORMATION :

Description : UPS CS638
Capacity : 600 VA / 300 W
AC Voltage : 160 – 250 V
AC Current : 1.6 A
AC Frequency : 50 ± 3 Hz
AC Protection Fuse : 3 A
DC INT Battery : 1 x 12 V, 7 Ah
DC Protection Fuse : 40 A
INV Waveform : SYNTHESIZED SINEWAVE
INV Voltage : 220 ± 5% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : >80 %
CHG Type : CONSTANT VOLTAGE
CHG Voltage : 13.6 V
CHG Current : 1.5 A
Transfer Time : <4 ms
Back Up Time : 10 min
Indicator : LED & BUZZER
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 340 x 86 x 158 mm
Weight : 7 Kg

UPS SIN 1100 C

PRODUK ICA UPS dan STABILIZER

ICA UPS SIN1100C Capacity 1600VA. Because the UPS is the true on-line system, conditioned power is provided continuously to the attached load. The UPS constantly regulates and filter the AC input voltage and supply a clean and stable AC voltage to the output and charge the batteries. When the AC input voltage low or loss, the UPS protects the load instantaneously and supply a stable AC voltage without any transfer time.

TECHNICAL INFORMATION :

Description : UPS SIN1100C
Capacity : 1600 VA / 1040 W
AC Voltage : 185 – 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 84 V
DC INT Battery : 7 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 95.2 V
INV Wave Form : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
BZR UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
BZR AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 510 x 205 x 450 mm
Weight : 50 Kg

UPS ST 531 C

ICA UPS ST531C Capacity 1000VA. Because the UPS is the true on-line system, conditioned power is provided continuously to the attached load. The UPS constantly regulates and filter the AC input voltage and supply a clean and stable AC voltage to the output and charge the batteries. When the AC input voltage low or loss, the UPS protects the load instantaneously and supply a stable AC voltage without any transfer time.

TECHNICAL INFORMATION :

Description : UPS ST531C
Capacity : 1000 VA / 500 W
AC Voltage : 160 – 250 V
AC Frequency : 50 ± 3 Hz
AC Protection : 5 A
DC Voltage : 24 V
DC INT Battery : 2 x 12 V, 7 Ah
DC Protection : FUSE
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 27.2 V
INV Wave Form : SINEWAVE
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time AC Fail : 0 ms
Transfer Time STS : 2 ms Inverter to Bypass
: ZERO CROSSING BYPASS TO INVERTER
Back Up Time : 10 min
BZR AC Input Low / Fail : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 395 x 190 x 290 mm
Weight : 14.5 Kg

UPS ST 831 C

ICA UPS ST831C Capacity 1600VA. Because the UPS is the true on-line system, conditioned power is provided continuously to the attached load. The UPS constantly regulates and filter the AC input voltage and supply a clean and stable AC voltage to the output and charge the batteries. When the AC input voltage low or loss, the UPS protects the load instantaneously and supply a stable AC voltage without any transfer time.

TECHNICAL INFORMATION :

Description : UPS ST831C
Capacity : 1600 VA / 800 W
AC Voltage : 160 – 250 V
AC Frequency : 50 ± 3 Hz
AC Protection : 7 A
DC Voltage : 48 V
DC INT Battery : 4 x 12 V, 7 Ah
DC Protection : FUSE
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 54.4 V
INV Wave Form : SINEWAVE
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time AC Fail : 0 ms
Transfer Time STS : 2 ms Inverter to Bypass
: ZERO CROSSING BYPASS TO INVERTER
Back Up Time : 10 min
BZR AC Input Low / Fail : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 395 x 190 x 290 mm