UPS SIN 1100 C

PRODUK ICA UPS dan STABILIZER

ICA UPS SIN1100C Capacity 1600VA. Because the UPS is the true on-line system, conditioned power is provided continuously to the attached load. The UPS constantly regulates and filter the AC input voltage and supply a clean and stable AC voltage to the output and charge the batteries. When the AC input voltage low or loss, the UPS protects the load instantaneously and supply a stable AC voltage without any transfer time.

TECHNICAL INFORMATION :

Description : UPS SIN1100C
Capacity : 1600 VA / 1040 W
AC Voltage : 185 – 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 84 V
DC INT Battery : 7 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 95.2 V
INV Wave Form : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
BZR UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
BZR AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 510 x 205 x 450 mm
Weight : 50 Kg

UPS SIN 1500 C

ICA UPS SIN1500C Capacity 2500VA. Because the UPS is the true on-line system, conditioned power is provided continuously to the attached load. The UPS constantly regulates and filter the AC input voltage and supply a clean and stable AC voltage to the output and charge the batteries. When the AC input voltage low or loss, the UPS protects the load instantaneously and supply a stable AC voltage without any transfer time.

TECHNICAL INFORMATION :

Description : UPS SIN1500C
Capacity : 2500 VA / 1625 W
AC Voltage : 185 – 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 120 V
DC INT Battery : 10 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 136 V
INV Wave Form : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
BZR UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
BZR AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 610 x 230 x 475 mm
Weight : 74 Kg

UPS SIN 2100 C

ICA UPS SIN2100C Capacity 3100VA. Because the UPS is the true on-line system, conditioned power is provided continuously to the attached load. The UPS constantly regulates and filter the AC input voltage and supply a clean and stable AC voltage to the output and charge the batteries. When the AC input voltage low or loss, the UPS protects the load instantaneously and supply a stable AC voltage without any transfer time.

TECHNICAL INFORMATION :

Description : UPS SIN2100C
Capacity : 3100 VA / 2015 W
AC Voltage : 185 – 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 120 V
DC INT Battery : 10 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 136 V
INV Wave Form : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
BZR UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
BZR AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 630 x 265 x 610 mm
Weight : 85 Kg

UPS SIN 3100 C

ICA UPS SIN3100C Capacity 5000VA. Because the UPS is the true on-line system, conditioned power is provided continuously to the attached load. The UPS constantly regulates and filter the AC input voltage and supply a clean and stable AC voltage to the output and charge the batteries. When the AC input voltage low or loss, the UPS protects the load instantaneously and supply a stable AC voltage without any transfer time.

TECHNICAL INFORMATION :

Description : UPS SIN3100C
Capacity : 5000 VA / 3250 W
AC Voltage : 185 – 250 V
AC Frequency : 50 ± 5% Hz
AC Protection : NO FUSE BREAKER
DC Voltage : 192 V
DC INT Battery : 16 x 12 V, 7 Ah
DC Protection : NO FUSE BREAKER
CHG Topology : SWITCHING REGULATION
CHG Floating Voltage : 217.6 V
INV Wave Form : SINUSOIDA
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : > 85%
Transfer Time When AC In Loss : 0 ms
Static Transfer Switch : 2 ms From Inverter to Bypass, 0 ms Back To Inverter
Back Up Time : 10 min
BZR UPS In Bypass Condition : INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
BZR AC In Abnormal : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 630 x 265 x 690 mm
Weight : 110 Kg