UPS CS 1238

PRODUK ICA UPS dan STABILIZER

ICA UPS CS-1238 Capacity 1200 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.

TECHNICAL INFORMATION :

Description : UPS CS1238
Capacity : 1200 VA / 600 W
AC Voltage : 160 – 250 V
AC Current : 2.96 A
AC Frequency : 50 ± 3 Hz
AC Protection Fuse : 5 A
DC INT Battery : 2 x 12 V, 7 Ah
DC Protection Fuse : 40 A
INV Waveform : SYNTHESIZED SINEWAVE
INV Voltage : 220 ± 5% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : >80 %
CHG Type : CONSTANT VOLTAGE
CHG Voltage : 27.2 V
CHG Current : 1.5 A
Transfer Time : <4 ms
Back Up Time : 10 min
Indicator : LED & BUZZER
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 375 x 135 x 201 mm
Weight : 14 Kg

UPS RN 1200

ICA UPS RN-1200 Capacity 1200 VA, inverter works only when the AC input voltage low or loss. When the AC input voltage in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage low or loss inverter will replace it and supply a stable AC voltage within a very short transfer time.

TECHNICAL INFORMATION :

Description : UPS RN1200
Capacity : 1200 VA / 600 W
AC Voltage : 160 – 250 V
AC Frequency : 50 ± 3 Hz
AC Protection : 6.3 A
DC Voltage : 24 V
DC INT Battery : 2 x 12 V, 7 Ah
DC Protection : FUSE
CHG Topology : CONSTANT VOLTAGE
CHG Floating Voltage : 27.2 V
INV Wave Form : SINEWAVE
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 80%
Transfer Time : <4 ms
Back Up Timel : 10 min
BZR AC Input Low / Fail : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR AC Input High : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 450 x 435 x 87 mm
Weight : 20 Kg

UPS RN 2000

ICA UPS RN-2000 Capacity 2000 VA, inverter works only when the AC input voltage low or loss. When the AC input voltage in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage low or loss inverter will replace it and supply a stable AC voltage within a very short transfer time.

TECHNICAL INFORMATION :

Description : UPS RN2000
Capacity : 2000 VA / 1000 W
AC Voltage : 160 – 250 V
AC Frequency : 50 ± 3 Hz
AC Protection : 10 A
DC Voltage : 36 V
DC INT Battery : 3 x 12 V, 7 Ah
DC Protection : FUSE
CHG Topology : CONSTANT VOLTAGE
CHG Floating Voltage : 40.8 V
INV Wave Form : SINEWAVE
INV Distorsion : < 3% THD
INV Topology : PULSE WIDTH MODULATION (PWM)
INV Voltage : 220 ± 2% V
INV Frequency : 50 ± 1% Hz
INV Efficiency : ± 80%
Transfer Time : <4 ms
Back Up Timel : 10 min
BZR AC Input Low / Fail : INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
BZR AC Input High : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
BZR Battery Low : INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp : 0 – 40 °C
Dimension(DxWxH) : 450 x 435 x 87 mm
Weight : 24 Kg